END POSITION SIGNALING ON MANUAL VALVES

Limit switches are available for mounting on manual operated ball valves and butterflyvalves.
Limit switch box which is prepared for ISO F05 flange drilling, and long stem is suitable for bracket MSH which can be mounted to the valve flange with ISO 5211 connection.
Double sensors from Pepperl & Fuchs, IFM or similar, which normally are for actuator connection 80x30mm can be used with bracket MSH-EPV: This is connected to the valve flange with ISO 5211 connection.
A special nut is mounted to the valve shaft, which transfer the valve travel to the limitswitches.

Properties
  • MSH-EPV brackets are avaliable in different types of  ISO 5211 connections
  • With removal of the "black plate" connected to MSH-EPV, is then transferred to a MSH bracket
  • Bracket high is adjustable in 5 different highs
  • Nut size can be changed for connection to the differenmt brackets
  • Brackets and nuts are delivered in stainless steel material AISI 304 and AISI 303
BRACKETS FOR END POSITION SIGNALING ON MANUAL VALVES
Product number Type ISO 5211 endebryter side ISO 5211 ventil side Nut size
04130206 MSH - EPV F-05 F-05 M5
04130207 MSH-EPV F-05 F-07 M6
04130208 MSH-EPV F-05 F-10 M8
04130209 MSH - EPV F-05 F-04 M5